Attribution Tables of Division B 6.4.1.1.

Table 6.4.1.1.
Objectives and Functional Statements Attributed to the Acceptable Solutions in Part 6
Forming part of Sentence 6.4.1.1.(1)
Acceptable Solutions Functional Statements and Objectives(1)
6.2.1.1. Good Engineering Practice
(1) (a) to (e) [F31,F51-OP1.1]
(a) to (c) and (e) to (i) [F40,F50,F51,F52,F54,F63-OH1.1]
(a),(b),(c),(e),(f),(g),(h) [F50,F51,F52,F54,F63-OH1.2,OH1.3]
[F50,F31,F63,F51,F54,F52-OS3.2,OS3.4]
(d) [F01-OS1.1]
6.2.1.3. Structural Movement
(1) [F23-OS3.1]
[F51,F63,F50-OH1.1,OH1.2,OH1.3]
6.2.1.4. Installation Standards
(1) [F43-OS1.1]
[F43-OS3.4]
[F43-OP1.1]
(2) [F40,F44,F50-OH1.1]
[F44-OS3.4]change end
6.2.1.8. Installation – General
(1) [F82-OS1.1]
[F82-OS3.4]
[F82-OP1.1]
(2) [F31-OS3.1]
(3) [F81-OS3.2,OS3.3,OS3.4]
[F81-OS1.1]
6.2.1.9. Expansion, Contraction and System Pressure
(1) [F20-OS3.2]
6.2.1.10. Asbestos
(1) [F43-OH1.1]
6.2.1.11. Access Openings
(1) [F36-OS3.6]
6.2.2.1. Required Ventilation
(1) [F50,F31,F63,F51,F54,F52-OS1.1]
[F50,F31,F63,F51,F54,F52-OP1.1]
(2) [F50-OH1.1]
change begin(4) [F50-OH1.1]change end
6.2.2.2. Natural Ventilation
(1) [F50-OH1.1]
(2) [F50-OH1.1]
6.2.2.3. Ventilation of Storage Garages
(1) [F50,F44-OS3.4]
(2) [F44-OS3.4]
(3) [F44-OS3.4]
(4) [F50,F44-OS3.4]
(5) [F50,F44-OH1.1]
[F50,F44-OS3.4]
6.2.2.4. Cleaning Devices
(1) [F40,F43,F44,F50-OH1.1]
[F44-OS3.4]
6.2.2.5. Air Contaminants
(1) [F44-OS3.4]
[F44-OH1.1]
(2) [F44-OH1.1]
(3) [F52-OH1.1]
6.2.2.6. Hazardous Gases, Dusts or Liquids
(1) [F01-OP1.1]
[F01-OS1.1]
(2) [F01-OS1.1]
[F01-OP1.1]
6.2.2.7. Commercial Cooking Equipment
(1) [F01,F44-OS1.1]
[F01,F44-OP1.1]
(2) [F02,F81-OS1.2]
[F02,F81-OP1.2]
6.2.2.8. Crawl Spaces and Attic or Roof Spaces
(1) [F61,F63,F41-OH1.1,OH1.3]
6.2.3.2. Materials in Air Duct Systems
(2) [F20,F80-OH1.1,OH1.2]
(3) [F81,F44-OS3.4]
[F81-OH1.1]
(4) [F20,F80-OH1.1,OH1.2]
6.2.3.3. Connections and Openings in Air Duct Systems
(1) [F81-OH1.1,OH1.2]
[F81,F44-OS3.4]
(2) [F82-OS1.1]
6.2.3.4. Duct Coverings and Linings
(3) [F81-OH1.1,OH1.2]
[F81-OS1.1]
[F81-OP1.1]
6.2.3.5. Underground Ducts
(1) (a) [F44,F81-OH1.2,OH1.3]
(b) [F44,F81-OH1.1]
(c) [F44,F81-OH1.1]
(2) [F81-OH1.1,OH1.2,OH1.3]
6.2.3.8. Exhaust Ducts and Outlets
(1) [F44-OH1.1]
(2) [F44-OH1.1]
(3) [F81-OH1.1]
[F81-OH1.2]
(4) [F81-OH1.1]
[F81-OH1.2]
(5) [F81-OH1.1]
(6) [F81-OH1.1]
(7) [F81-OS1.1]
(8) [F40,F44,F50,F52-OH1.1]
[F44-OS3.4]
[F01-OS1.1]
[F01-OP1.1]
(9) [F40,F44,F50,F52-OH1.1]
[F44-OS3.4]
[F01-OS1.1]
[F01-OP1.1]
(10) [F81-OH1.1]
(11) [F81,F44-OH1.1]
[F81,F44-OS1.1]
(12) [F81,F44-OH1.1]
(13) [F81-OH1.2]
[F81,F44-OH1.1]
6.2.3.9. Interconnection of Systems
(1) [F44-OS1.1]
[F40-OH1.1]
(2) [F81,F44-OH1.1]
[F81,F44-OS1.1]
[F81,F44-OP1.1]
(3) [F81,F44-OH1.1]
6.2.3.11. Makeup Air
(1) [F50,F81-OH1.1]
[F44,F81-OS3.4]
(2) [F81-OH1.1]
[F81,F44-OS3.4]
(3) [F81-OH1.2]
6.2.3.12. Supply, Return, Intake and Exhaust Air Openings
(1) [F30-OS3.1]
[F81-OH1.2]
(2) [F81-OH1.1]
[F81,F44-OS3.4]
(3) [F81-OH1.1]
(4) [F82,F81-OH1.1]
[F82-OS3.4]
6.2.3.13. Filters and Odour Removal Equipment
(1) [F80-OS1.1]
[F80-OP1.1]
(2) [F30-OS3.3]
[F81,F43-OH1.1]
(3) [F82-OH1.1]
(4) [F82-OH1.1]
6.2.3.14. Air Washers and Evaporative Cooling Sections or Towers
(1) [F80,F81-OS1.1]
[F80,F81-OP1.1]
(2) [F82-OH1.1]
(3) [F01,F81-OS1.1]
6.2.3.15. Fans and Associated Air-Handling Equipment
(1) [F81,F44-OH1.1]
[F81,F44-OS3.4]
(2) [F81-OH1.1]
6.2.3.20. Return-Air System
(3) [F10-OS1.5]
6.2.4.1. Carbon Monoxide Alarms
(2) (a),(b),(d) [F44-OS3.4]
(c) [F81-OS3.4]
(3) [F44-OS3.4]
(4) [F44-OS3.4]
(5) [F44-OS3.4]
6.2.5.2. Appliances Installed Outside the Building
(1) [F81-OP1.1]
[F81-OH1.1]
[F81-OS1.1]
6.2.6.1. Applicable Standard
(1) [F81-OS1.1]
6.2.7.1. Clearances
(1) [F01-OP1.1]
[F01-OS1.1]
6.2.8.1. Lining or Backing
(1) [F01-OS1.1]
[F01-OP1.1]
(2) [F01-OS1.1]
6.2.9.1. Piping Materials and Installation
(1) [F20-OS3.2,OS3.4]
(2) [F21-OH1.1]
(3) [F20-OS2.2]
6.2.9.2. Insulation and Coverings
(1) [F20,F30-OS3.2,OS3.4]
(2) [F31-OS3.2]
6.2.9.3. Clearances
(1) [F01-OS1.1]
[F01-OP1.1]
6.2.9.4. Surface Temperature
(1) [F31-OS3.2]
6.2.9.5. Protection
(1) [F01-OS1.1]
[F01-OP1.1]
6.2.10.1. Cooling Units
(1) [F43,F81-OS3.4]
6.2.11.1. Storage Bins
(1) [F30,F31,F43-OS3.2,OS3.4]
(2) [F01-OS1.1]
[F01-OP1.1]
(3) [F30-OH2.1]
(4) [F01-OS1.1]
[F01-OP1.1]
6.2.11.2. Ash Storage Bins
(1) [F01-OS1.1]
[F01-OP1.1]
(2) [F01-OS1.1]
[F01-OP1.1]
6.2.12.2. General Ventilation
(1) (a),(b),(d),(e) [F01-OS1.1]
(c) [F02-OP1.2]
(c) [F02-OS1.2] [F81,F82-OS1.1]
(2) [F81,F11-OS1.1]
6.2.12.3. Enclosure Exhaust Ventilation
(1) (a),(c),(d) [F01-OS1.1]
(b) [F02-OP1.2]
(e) [F12-OP1.1,OP1.2]
(a) [F02-OP1.2]
(b) [F02-OS1.2] [F81-OS1.1]
(e) [F12-OS1.1,OS1.2]
(a) [F02-OS1.2]
(a) [F01-OS1.1]
6.2.12.4. Enclosure Construction
(1) (a) [F02-OS1.2] Applies to portion of Code text: “… be constructed of noncombustible materials …”
(b) [F02-OP1.2]
(a) [F02-OP1.2] Applies to portion of Code text: “… be constructed of noncombustible materials …”
(a) [F80-OS3.4] Applies to portion of Code text: “… be constructed of … materials … chemically resistant to the dangerous goods vapours and particles being exhausted …”
(b) [F02-OS1.2] [F82-OS1.1]
(a) [F80-OS1.1] Applies to portion of Code text: “… be constructed of … materials … chemically resistant to the dangerous goods vapours and particles being exhausted …”
(a) [F01-OS1.1] Applies to portion of Code text: “… be constructed of … materials compatible with … the dangerous goods vapours and particles being exhausted …”
(3) [F02-OS1.2]
[F02-OP1.2]
6.3.1.2. Masonry or Concrete Chimneys
(2) [F01-OS1.1]
[F01-OP1.1]
6.3.1.3. Metal Smoke Stacks
(1) [F01-OS1.1]
[F01-OP1.1]
6.3.1.4. Lightning Protection Systems
(1) [F01,F81-OS1.1]
[F01,F81-OP1.1]
6.3.1.5. Access Ladders
(1) [F20,F80-OS3.1]
(2) [F30-OS3.1]
Notes to Table 6.4.1.1.:

(1) See Parts 2 and 3 of Division A.

contentHistory