Division A
Compliance, Objectives and Functional Statements
Part 1 — Compliance
Section 1.3. Divisions A, B and C of this
By-law

1.3.1. General
1.3.1.1. Scope of Division A
1) Division A contains the compliance and application provisions, objectives and
functional statements of this
By-law
.
By-law
. 
1.3.1.2. Scope of Division B
1) Division B contains the acceptable solutions of this
By-law
.
By-law
. 
1.3.1.3. Scope of Division C
1) Division C contains the administrative provisions of this
By-law
.
By-law
. 
1.3.1.4. Internal Cross-references
1) Where the Division of a referenced provision is not specified in this
By-law
, it shall mean that the referenced provision is in the same Division as the referencing provision.
By-law
, it shall mean that the referenced provision is in the same Division as the referencing provision.

1.3.2. Application of Division A
1.3.2.1. Application of Parts 1, 2 and 3
1) Parts 1, 2 and 3 of Division A apply to all buildings covered in this
By-law
. (See Article 1.1.1.1.)
By-law
. (See Article 1.1.1.1.) 
1.3.3. Application of Division B
1.3.3.1. Application of Parts 1, 7, 8 and 10
1) Parts 1, 7, 8 and 10 of Division B apply to all buildings covered in this
By-law
. (See Article 1.1.1.1.)
By-law
. (See Article 1.1.1.1.) 
1.3.3.2. Application of Parts 3, 4, 5 and 6
1) Parts 3, 4, 5, and 6 of Division B apply to all buildings described in Article 1.1.1.1. and
a) classified as post-disaster buildings,
b) used for major occupancies classified as
i) Group A, assembly occupancies,
ii) Group B, care,
treatment
or detention occupancies, or
treatment
or detention occupancies, oriii) Group F, Division 1, high-hazard industrial occupancies, or
c) exceeding 600 m2 in building area or exceeding 3 storeys in building height used for major occupancies classified as
i) Group C, residential occupancies,
ii) Group D, business and personal services occupancies,
iii) Group E, mercantile occupancies, or
iv) Group F, Divisions 2 and 3, medium- and low-hazard industrial occupancies.
3) Part 5 applies to all Group C multi-family buildings and Artist Live/Work Studios that are
a) more than 2 storeys in building height, or
b) more than 600 m2 in building area excluding firewalls.
4) Notwithstanding Sentence (1), Section 3.8 applies to all Part 9 buildings.

1.3.3.3. Application of
Parts 9, 11 and 12

1)
Except as provided in Sentences 1.3.3.2.(2) and (3),
Part 9 of Division B applies to all buildings described in Article 1.1.1.1. of 3 storeys or less in building height, having a building area not exceeding 600 m2, and used for major occupancies classified as
Except as provided in Sentences 1.3.3.2.(2) and (3),
Part 9 of Division B applies to all buildings described in Article 1.1.1.1. of 3 storeys or less in building height, having a building area not exceeding 600 m2, and used for major occupancies classified asa) Group C, residential occupancies (see Appendix Note A-9.1.1.1.(1) of Division B),
b) Group D, business and personal services occupancies,
c) Group E, mercantile occupancies, or
d) Group F, Divisions 2 and 3, medium- and low-hazard industrial occupancies.

2)
Part 11 applies to the alteration, rehabilitation, renovation, repair, addition or change of major occupancy of an existing building and as defined in Appendix Note A-11.2.1.2. of Division B.
Part 11 applies to the alteration, rehabilitation, renovation, repair, addition or change of major occupancy of an existing building and as defined in Appendix Note A-11.2.1.2. of Division B. 3) Part 12 applies to the design and construction of all new marinas and float homes; and to existing marinas and existing float homes as defined in Article 11.2.1.11. of Division B.

1.3.3.4. Building Size Determination
1) Where a firewall divides a building, each portion of the building so divided shall be considered as a separate building, except when this requirement is specifically modified in other parts of this
By-law
. (See Appendix A.)
By-law
. (See Appendix A.) 
2) Except as permitted in Sentence (3), where portions of a building are completely separated by a vertical fire separation that has a fire-resistance rating of not less than 1 h and extends through all storeys and service spaces of the separated portions, each separated portion is permitted to be considered as a separate building for the purpose of determining building height, provided
a) each separated portion is not more than 3 storeys in building height and is used only for residential occupancies, and
b) the unobstructed path of travel for a firefighter from the nearest street to one entrance of each separated portion is not more than 45 m.
(See Appendix A.)3) The vertical fire separation referred to in Sentence (2) may terminate at the floor assembly immediately above a basement provided the basement conforms to Article 3.2.1.2. of Division B.
1.3.3.5.
Air Space Subdivision
1) Where a subdivision of land creates an air space parcel boundary in or through a building, which otherwise complies with this By-law, such building or a portion of the building may, at the discretion of the Chief Building Official, be considered as a single building not requiring internal firewalls or party walls along air space parcel boundaries if legal agreements are registered against title to all air space parcels and the remainder whereby
a) all relevant owners grant easements necessary to ensure common access to the fire and life safety systems and exits required for the building to function as a single building and to allow the owners to operate and maintain the building and its common systems, and
b) all owners grant a covenant to the City on terms acceptable to its Director of Legal Services and the Chief Building Official whereby the owners
i) acknowledge and agree that they have requested the Chief Building Official to treat the building as a single building,
ii) release and indemnify the City and the Chief Building Official for, without limitation, all liability arising from the Chief Building Official agreeing to treat the building or a portion of the building as a single building for the purposes of this By-law, and
iii) agree to inspect, test and keep in good repair and good working order all common fire and life safety systems, common utilities and shared exits located on their parcel and, to the extent necessary, use the easements referred to in Clause (1)(a) for that purpose.
1.3.3.6. Automatic Sprinkler Systems
1) Except for buildings described in Sentence (2), all newly constructed buildings shall be provided with an automatic sprinkler system designed and installed in accordance with Article 3.2.5.12. of Division B.
2) The following buildings are not required to be sprinklered
a) temporary buildings conforming to Subsection 1.6.8. of Division C, and tents and air-supported structures conforming to Subsection 3.1.6. of Division B,
b) one storey non-residential storage buildings less than 100 m2 in building area, and having a limiting distance on all sides of not less than 15 m,
c) one storey detached residential garages and carports,
d) one storey detached buildings which are accessory to one- and two-family dwellings, and which are less than 50 m2 in building area,
e) industrial or hazardous occupancies where the Chief Building Official accepts that the installation of an automatic sprinkler system would represent a hazard to the occupants or would be incompatible with the use of the building,
f) public concession stands and changing room buildings less than 100 m2 in building area and having a limiting distance on all sides of not less than 15 m,
g) ticket kiosks,
h) bleachers which do not contain roofed occupancies,
j) greenhouses used solely for the growing of plants where no public admittance is permitted,
and
k) one storey portable classroom buildings of less than 100 m2 in building area with an occupancy classification of Group A Division 2 or Group D. [See Appendix A.]

1.3.4. Application of Division C
1.3.4.1.
Application of Parts 1, 2 and 3

1) Parts 1
, 2 and 3
of Division C apply to all buildings covered in this
By-law
. (See Article 1.1.1.1.)
, 2 and 3
of Division C apply to all buildings covered in this
By-law
. (See Article 1.1.1.1.) 